What size generator do I need for a house?
It depends on what you want to run, not on the square footage. Using the site's typical appliance values: a 3,500 W portable covers a basic set of essentials, about 12,000 W covers essentials plus a well pump and kitchen, and running everything at once, including central AC and an electric range, lands in standby territory around 22 kW.
Three common scopes (typical values)
| Scope | Running | Peak at start | With 30% headroom (run / start) | Class to look for |
|---|---|---|---|---|
| Essentials: fridge, freezer, furnace blower, sump pump, Wi-Fi, lights, phones | 1,635 W | 3,235 W | 2,126 W / 4,206 W | 3,500 W portable |
| Essentials plus microwave, coffee maker, TV and a 240 V well pump | 5,235 W | 7,235 W | 6,806 W / 9,406 W | 12,000 W large portable |
| Everything on the calculator's whole-house list (18 items, including central AC and electric range) | 14,545 W | 20,045 W | 18,909 W / 26,059 W | 22 kW standby |
Peak at start = all running loads plus the single largest start-up extra, because motors rarely start in the same instant. The third row assumes every item runs at once; in practice you can leave the range and AC off and use a smaller unit.
Square footage is a poor guide
A big house with gas heat and a gas range can need less than a small all-electric one. The loads that move the answer are the 240 V ones: central AC (3,500 W running, 9,000 W start, typical), an electric range, a well pump, an electric dryer or water heater. Decide which of those you really need in an outage, then tick them in the generator size tool.
Hooking it up to a house
- A portable generator feeds the house through an inlet (NEC 702.12 covers outdoor generator sets, inlets and disconnects) and an interlock or transfer switch (NEC 702.5, transfer equipment). Never back-feed a panel with a cord or a "suicide cable".
- The system must be able to carry the load it is connected to, or the transfer equipment must shed load (NEC 702.4, capacity and rating). A load calculation under Article 220 is how you check it: try the service load calculator.
- A 3,500 W portable gives about 29 A at 120 V; a 7,500 W unit gives about 31 A at 240 V (7,500 / 240). Pick the inlet and wire for that current with the inlet breaker and wire tool and the interlock or transfer switch chooser.
- Fuel is the other cost: see fuel and runtime. Run generators outdoors, away from windows. See the safety checklist.
Open the generator size tool with this house filled in · Plan my whole backup system
Not sure a generator is the right type? Compare generator, power station and home battery, or see the 10-year cost.
All appliance figures are typical values from the calculator, not measurements of your home. The sums add 30% headroom (generator) or 25% (home battery inverter) and assume 90% of a home battery's rated capacity is usable (typical for LFP; check the unit). We list no prices and have not hands-on tested any product. Local amendments apply, and the hookup work needs a licensed electrician and a permit where required.
Back to the calculator · How many home batteries to run a house