How many home batteries do I need to run my house?
Count kilowatt-hours for the hours you want to cover and kilowatts for what runs at once. Using the site's typical appliance values and a 24-hour outage: about 9 kWh and a 2 kW inverter for essentials, about 12.5 kWh and 7 kW with a well pump and kitchen, and about 37 kWh and 18 kW for everything including central AC and an electric range.
Three common scopes, 24 hours (typical values)
| Scope | Energy per day | Battery to look for (nominal) | Continuous inverter | Surge |
|---|---|---|---|---|
| Essentials: fridge, freezer, furnace blower, sump pump, Wi-Fi, lights, phones | 8.4 kWh | about 9.3 kWh | 2.1 kW | 3.3 kW |
| Essentials plus microwave, coffee maker, TV and a 240 V well pump | 11.3 kWh | about 12.5 kWh | 6.6 kW | 7.3 kW |
| Everything on the whole-house list (18 items, including central AC and electric range) | 33.4 kWh | about 37.1 kWh | 18.2 kW | 20.1 kW |
Longer outages
| Scope | 24 hours | 72 hours |
|---|---|---|
| Essentials | 9.3 kWh | 27.9 kWh |
| Essentials plus well pump and kitchen | 12.5 kWh | 37.6 kWh |
| Whole-house list | 37.1 kWh | 111.3 kWh |
Energy = watts × duty cycle × hours switched on per day, summed, scaled to the outage length, then divided by 0.90 usable. Many people add solar to stretch these numbers: see solar and battery sizing. Home batteries are sold in modules, so how many you need is the nominal kWh divided by the module size on the maker's spec sheet.
What to check beyond kWh
- Power matters as much as energy. A 240 V load (well pump, central AC, range) needs a split-phase inverter, or stacked units, and the inverter's continuous and surge ratings must cover it. Check the tool's leg balance: the two 120 V legs should carry similar current.
- A battery that backs up the whole panel or a critical-loads subpanel is a permitted, inspected installation by a licensed electrician (NEC Article 706 for energy storage systems; transfer equipment under 702.5 / the manufacturer's listed system). Local amendments apply.
- Back up fewer circuits to shrink the battery: the critical loads planner picks which circuits matter.
- Check your panel can take the added equipment: will it fit my panel?
Open the home battery tool with this house filled in · Plan my whole backup system
Weighing a battery against a generator? See the 10-year cost compare or the chooser.
All appliance figures are typical values from the calculator, not measurements of your home. The sums add 30% headroom (generator) or 25% (home battery inverter) and assume 90% of a home battery's rated capacity is usable (typical for LFP; check the unit). We list no prices and have not hands-on tested any product. Local amendments apply, and the hookup work needs a licensed electrician and a permit where required.