Can a power station run an RV air conditioner?
A typical 13,500 BTU rooftop RV air conditioner draws about 1,400 W while the compressor runs and about 4,000 W for the moment it starts. Many 2,000 W-class stations cannot start it without a soft-start kit, and even then a 3 kWh station runs it for only a few hours.
Typical numbers
| Item | Typical running | Typical start-up surge | Average with cycling |
|---|---|---|---|
| Rooftop AC, 13,500 BTU | about 1,400 W | about 4,000 W | about 700 W (compressor on half the time) |
| Rooftop AC, 15,000 BTU | about 1,600 W | about 4,500 W | about 800 W |
Typical planning values, not measurements of a specific unit. The nameplate on your AC (running amps, locked-rotor amps) wins; hot weather keeps the compressor on far more than half the time.
Worked example
13,500 BTU AC at about 700 W average, with 85% of rated capacity usable and nothing else running:
| Battery rating | Usable | AC runtime (average) |
|---|---|---|
| 2,000 Wh | 1,700 Wh | about 2.4 hours |
| 3,000 Wh | 2,550 Wh | about 3.6 hours |
| 5,000 Wh | 4,250 Wh | about 6.1 hours |
In a hot afternoon with the compressor running most of the time (closer to 1,400 W) expect about half of those hours.
Good to know
- The start-up surge decides whether it runs at all. You want a surge rating of about 4,400 W (4,000 W plus a 10% margin), or a soft-start kit that cuts the peak; see the soft-start check.
- An AC alone will empty most stations in an afternoon. A generator or a very large battery with solar is the practical way to cool an RV for a day or more; see generator size and solar panels to recharge.
- A 30 A shore connection is 3,600 W on one 120 V leg; a 50 A one is two legs. Check the AC, microwave and water heater together in the RV power check.
- Never plug a generator or station into a wall outlet with a double-male cord to feed an RV or a house. Use the unit's own outlets, or a proper inlet with an interlock or transfer switch installed by a licensed electrician.
Open the RV power check with an AC, fridge and converter filled in
Appliance figures are typical values, not measurements of your device. The sums assume 85% of a battery's rated capacity reaches your outlets (how the numbers work). We list no prices and have not hands-on tested any product.
Back to the calculator · Window AC · Central AC · 30 amp hookup