Can a power station run a mini-split heat pump?

Sometimes, for a few hours. A typical 12,000 BTU inverter mini-split averages about 450 W, so a 2 kWh station runs it roughly 3.8 hours, but most units are wired for 208-230 V and need a station with a 240 V output or a proper inlet. Check the label on yours.

Typical numbers

ItemTypical runningTypical start-up drawAverage over a day
Mini-split, 12,000 BTU, inverter, 208-230 Vabout 900 W at full output, 200 to 400 W at part loadabout 1,200 W (inverters start gently)about 450 W at 50% duty

Typical values only: SEER2 rating, outdoor temperature and how hard it is working all move the draw. The nameplate gives minimum circuit ampacity and max fuse size, which are not running watts; a plug-in watt meter or the manual's rated input power is better.

Worked example

900 W × 50% average duty = 450 W. With 85% of rated capacity usable:

Battery ratingUsableRuntime
1,000 Wh850 Whabout 1.9 hours
2,000 Wh1,700 Whabout 3.8 hours
3,000 Wh2,550 Whabout 5.7 hours

A full 8 hours at this duty needs about 4,200 Wh of rated capacity. In mild weather the unit runs well below full output and lasts longer.

Good to know

Open the calculator with a mini-split filled in

Appliance figures are typical values, not measurements of your device: the label or a plug-in watt meter on yours wins. The sums assume 85% of a battery's rated capacity reaches your outlets (how the numbers work). We list no prices and have not hands-on tested any product.