Power station for a gas furnace blower: size and runtime

A gas furnace makes heat with gas, but its blower fan, control board and igniter need mains power. In a winter outage the furnace will not run without electricity. The load is modest compared with electric heat, but the blower motor has a start-up surge.

Typical numbers

ItemTypical runningTypical start-up surgePer day
Gas furnace blower, board and igniter500 Wabout 1,500 Wabout 3,600 Wh

Typical values, assuming the blower runs about 30% of the time on a cold day. Variable-speed (ECM) blowers often draw far less; the nameplate on your furnace gives amps. Watts are roughly amps × 120.

Worked example

500 W × 24 h × 0.30 = 3,600 Wh a day, or about 150 W on average. With 85% of rated capacity usable:

Battery ratingUsableFurnace runtime
1,000 Wh850 Whabout 6 hours
2,000 Wh1,700 Whabout 11 hours
3,000 Wh2,550 Whabout 17 hours

Good to know

Open the calculator with a furnace blower filled in

Appliance figures are typical values, not measurements of your device: the label or a plug-in watt meter on yours wins. The sums assume 85% of a battery's rated capacity reaches your outlets (how the numbers work). We list no prices and have not hands-on tested any product.