Size My Backup

Can a power station run an electric water heater?

Usually not a portable one. A typical US electric tank water heater is a 240 V appliance with a heating element of about 4,500 W, and a portable station is normally 120 V with a 1,000 to 3,000 W output. The tank is insulated though, so the cheapest plan is to switch the heater off at its breaker and use the hot water already stored in it. A home battery or generator on an inlet with an interlock can run it when you need it.

Typical numbers

ItemTypical runningTypical start-up surge1 hour at 40% duty
Electric tank water heater, 240 Vabout 4,500 W while heatingabout 4,500 W (resistive element, no motor)about 1,800 Wh

Typical values: the element switches on and off with the thermostat, so the average over an hour of heavy use is well below peak. Elements are commonly 3,800 to 5,500 W; the nameplate on the tank gives yours, and the circuit is commonly a 30 A breaker. Many tanks have two elements that take turns rather than run together. A heat pump water heater draws far less, roughly 500 to 700 W, but check its label.

Worked example

4,500 W × 1 h × 0.40 = 1,800 Wh for each hour of heavy use. With 85% of rated capacity usable:

Battery ratingUsableHours of water heating
2,000 Wh1,700 Whabout 0.9 hours
5,000 Wh4,250 Whabout 2.4 hours
10,000 Wh8,500 Whabout 4.7 hours

Good to know

Open the calculator with an electric water heater filled in

Appliance figures are typical values, not measurements of your device: the label or a clamp meter on yours wins. The sums assume 85% of a battery's rated capacity reaches your outlets (how the numbers work). We list no prices and have not hands-on tested any product.

Back to the calculator · Electric dryer · Electric range